Past Projects & Accomplishments
Fort George G. Meade, MD
- Comprehensive Site Assessment at the Granite NIKE control site, MD;
the former large Dry Cleaning Facility, Ft. Meade, MD; and the former
Incinerator Facility and Trap and Skeet Shooting Range, Ft. Meade, MD
- Environmental chemistry, OE avoidance, geologic, and groundwater
investigations at 65 SWMUs, Ft. Meade, MDRI/FS, remedial design and
actions to clean up petroleum-contaminated soil and groundwater at the
heating plant, Ft. Meade, MD
- Geophysical investigations at 5 sites, Ft. Meade, MD to locate
utilities, USTs, drums, landfills, and UXOs
- Installation of wastewater flow monitoring devices at the wastewater
treatment plant, Ft. Meade, MD
- Geologic, geotechnical and groundwater investigations at the water
treatment plant, Ft. Meade, MD
USACE, Omaha District
- PRP search for the groundwater contaminated with chlorinated
solvents at the Raytheon Missile Plant, Lowell, MA
- Anomaly reacquisition and discrimination at the former Lowry Bombing
& Gunnery Range, CO
USACE, Kansas City District
- PA/SI at 14 sites at Ft. Riley, KS
- RI/FS at the Dry Cleaning Facility, Ft. Riley, KS. The facility is
contaminated with chlorinated solvents
- RI/FS at the former fire training pit, Marshall Air Field, Ft.
Riley, KS. Contaminants of concern include chlorinated solvents and
petroleum hydrocarbon
NASA GSFC, Greenbelt, MD
- Groundwater and surface water monitoring, sampling and laboratory analysis
- Waste management and monitoring well maintenance
- Groundwater modeling and risk assessment
Veterans Affairs Medical Center (VAMC), Martinsburg, WV
- PA/SI to investigate VAMC’s drinking water (strange odor
reported) and a leak in a fuel pipe
- RI/FS to define the extent of the fuel leak
USACE, Baltimore District
- 5-Year ID Contract for HTRW & MEC - $10M (2004-2009)
- OE digital geophysical mapping at Ft. Dix, NJ
- OE digital geophysical mapping at Spring Valley, VA
- Hydrographic Surveys at Coaches, Poplar & James Island,
Chesapeake Bay for assessment and monitoring of erosion associated with
beneficial use of dredged materials
USACE, Huntsville Center
- Geophysical prove-out (GPO) at Pole Mountain, Laramie, Wyoming
- GPO at the McKinley Range of Redstone Arsenal, AL
- OE avoidance and digital geophysical mapping at the former Boise Barracks, Boise, Idaho
- GPO, OE avoidance and digital geophysical mapping at Savanna Army Depot, IL
Dulles International Airport, VA
- Geophysical and geotechnical investigations for the design of
runway, taxiways, tunnels, terminal buildings, control towers,
utilities, parking garages, and parking Lots since 1996 through various
contracts
Anacostia River, DC for Louisiana State University
- Bathymetric, Marine Magnetic, Side-scan Sonar, Sub-bottom Profiling,
and Sediment Profile Imaging Surveys in 2 areas along the Anacostia
River near Navy Yard, DC
American History Museum, DC for Smithsonian Institute
- Remediation of sinkholes possibly caused by groundwater leaking into
the underlying Metro tunnels. Eight borings were installed and 3-
dimensional cross-hole seismic tomography and GPR surveys were
conducted
I-70/Rt. 85 Interchange Design for Maryland State Highway Administration
- Performed geophysical and geotechnical investigation for the remediation of sink activities. Tasks included soil borings, electromagnetic, resistivity tomography, seismic tomography surveys, specification development for grouting, and construction management during grouting
|